TABLE OF CONTENTS  
COMPONENT DRAWINGS  
Nameplate and Decals Assembly ...................... 34-35  
Mast/Tripod Assembly (GB12BW)...................... 36-37  
Fan Blower/Lamp Base Assembly (GB12BP) ....38-39  
Balloon/Lamp Guard Assembly (GB12BP) ........ 40-41  
Offset Pole Assembly (GB12BS) ........................42-43  
MQ GLOBUG LIGHTING  
SYSTEM  
Table Of Contents ..................................................... 2  
Parts Ordering Procedures ....................................... 3  
Safety Message Alert Symbols ................................. 4  
Rules For Safe Operation ...................................... 5-7  
Specifications ............................................................ 8  
Dimensions (GB12BW) ............................................. 9  
Dimensions (GB12BS) ............................................ 10  
Dimensions (GB12BP) ............................................ 11  
Floodlight Footcandle Plot ...................................... 12  
General Information ................................................ 13  
Major Components ............................................14-15  
Setup (GB12BW) ...............................................16-18  
Operation (GB12BW) .............................................. 19  
Shutdown (GB12BW/GB12BS) ............................... 19  
Storage (GB12BW/GB12BS) .................................. 19  
Setup (GB12BS) ................................................21-22  
Operation (GB12BS) ............................................... 23  
Maintenance ......................................................24-29  
Troubleshooting (Lamps) ........................................ 30  
Troubleshooting (Mast) ........................................... 31  
Explanation Of Codes In Remarks Column ............ 32  
Suggested Spare Parts ........................................... 33  
Terms and Conditions Of Sale — Parts .................. 50  
Specification and part number  
are subject to change without  
notice.  
PAGE 2 — GLOBUG LIGHTING SYSTEM — OPERATION AND PARTS MANUAL — REV. #2 (11/03/08)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Effective:January 1st, 2006  
PARTS ORDERING PROCEDURES  
Ordering parts has never been easier!  
Choose from three easy options:  
Best Deal!  
Order via Internet (Dealers Only)  
Orderpartson-lineusingMultiquip’sSmartEquipwebsite!  
:
If you have an MQ Account, to obtain a  
Username and Password, E-mail us at:  
View Parts Diagrams  
Order Parts  
PrintSpecificationInformation  
To obtain an MQ Account, contact your  
District Sales Manager for more information.  
Use the internet and qualify for a 5% Discount  
on Standard orders for all orders which include  
complete part numbers.*  
to log in and save!  
Order Parts  
Note: Discounts Are Subject To Change  
Fax your order in and qualify for a 2% Discount  
on Standard orders for all orders which include  
complete part numbers.*  
Order via Fax (Dealers Only)  
:
All customers are welcome to order parts via Fax.  
Domestic (US) Customers dial:  
1-800-6-PARTS-7 (800-672-7877)  
Note: Discounts Are Subject To Change  
Domestic (US) Dealers Call:  
1-800-427-1244  
Order via Phone:  
Non-Dealer Customers:  
International Customers should contact  
their local Multiquip Representatives for  
Parts Ordering information.  
Contact your local Multiquip Dealer for  
parts or call 800-427-1244 for help in  
locating a dealer near you.  
When ordering parts, please supply:  
Dealer Account Number  
Specify Preferred Method of Shipment:  
UPS/Fed Ex  
DHL  
Dealer Name and Address  
Priority One  
Ground  
Tr uck  
Shipping Address (if different than billing address)  
Return Fax Number  
Next Day  
Applicable Model Number  
Second/ThirdDay  
Quantity, Part Number and Description of Each Part  
AllordersaretreatedasStandardOrders  
andwillshipthesamedayifreceivedprior  
to 3PM PST.  
NOTE  
WE ACCEPT ALL MAJOR CREDIT CARDS!  
GLOBUG LIGHTING SYSTEM — OPERATION AND PARTS MANUAL — REV. #2 (11/03/08) — PAGE 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GB12BW/BS/BP LIGHTING SYSTEM SAFETY MESSAGE ALERT SYMBOLS  
Potential hazards associated with any of the GloBug  
Lighting Systems operation will be referenced with Hazard  
Symbols which appear throughout this manual, and will be  
referenced in conjunction with Safety Message Alert  
FORYOUR SAFETY AND THE SAFETY OF OTHERS!  
Safety precautions should be followed  
at all times when operating this  
equipment. Failure to read and  
understand the Safety Messages and  
Operating Instructions could result in  
Symbols.  
CAUTION - Equipment Damage Messages  
injury to yourself and others.  
Other important messages are provided throughout this  
manual to help prevent damage to your lighting system,  
other property, or the surrounding environment.  
This Owner's Manual has been  
developed to provide complete  
instructions for the safe and  
efficient operation of the MQ  
GloBug Lighting Systems.  
Before using any of the GloBug  
This lighting system, other  
property, or the surrounding  
environment could be  
damaged if you DO NOT  
Lighting Systems referenced in this manual, ensure that the  
operating individual has read and understands all instructions  
in this manual.  
follow instructions.  
SAFETY MESSAGE ALERT SYMBOLS  
The three (3) Safety Messages shown below will inform you  
about potential hazards that could injure you or others. The  
Safety Messages specifically address the level of exposure  
to the operator, and are preceded by one of three words:  
DANGER, WARNING, or CAUTION.  
DANGER  
You WILL be KILLED or SERIOUSLY injured if you DO  
NOT follow directions.  
WARNING  
You CAN be KILLED or SERIOUSLY injured if you DO  
NOT follow directions.  
CAUTION  
You CAN be INJURED if you DO NOT follow directions.  
PAGE 4 — GLOBUG LIGHTING SYSTEM — OPERATION AND PARTS MANUAL — REV. #2 (11/03/08)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GB12BW/BS/BP LIGHTING SYSTEM — RULES FOR SAFE OPERATION  
ALWAYS make sure that the GB12BW (tripod) lighting  
system is placed on secure firm level ground so that it  
cannot slide or shift around, endangering workers. Also  
WARNING - READTHIS MANUAL  
Failure to follow instructions in this manual may lead to  
Serious Injury or even Death. This equipment is to be  
operated by trained and qualified personnel only! This  
equipment is for industrial use only.  
keep the immediate area free of bystanders  
.
ALWAYS keep area behind lighting system clear of people  
while raising and lowering mast.  
The following safety guidelines should always be used  
when operating GloBug Lighting System.  
To prevent the lighting system from overturning, NEVER  
use in winds that exceed 22 mph(10m/s)  
.
To prevent the GB12BW (tripod) lighting system from  
tipping, ALWAYS place tripod on a firm flat surface.  
Surface slant should not exceed 5 degrees.  
The following safety guidelines should always be used when  
operating any GloBug Lighting System:  
GENERAL SAFETY  
The GloBug lighting system should only be used in  
temperatures between 23°-104° Fahrenheit (-5° to 40°  
Celsius). Failure to comply with these operating  
parameters could cause the lamp to malfunction and  
shorten the ballast life.  
DO NOT operate or service this  
equipment before reading this entire  
manual.  
This equipment should not be operated by persons under  
18 years of age.  
NEVER use any GloBug lighting system in rain, snow  
or areas of high humidity that could generate electrical  
storms.  
NEVER operate this equipment without proper protective  
clothing, shatterproof glasses, steel-toed boots and other  
protective devices required by the job.  
MAST  
MAST SAFETY  
When raising or lowering the mast, keep  
hands and fingers clear of the various  
mast sections, this will prevent hands  
and fingers from getting pinched.  
PINCH  
POINT  
NEVER operate this equipment when not feeling  
well due to fatigue, illness or taking medicine.  
NEVER operate this equipment under the influence of  
drugs or alcohol.  
CHECK the mast for any deformations. Replace mast if  
defective.  
NEVER attach anything to the mast.  
ALWAYS lower the mast when not in use, or if high winds  
or electrical storms are expected in the area  
.
Whenever necessary, replace nameplate, operation and  
safety decals when they become difficult read.  
Manufacturer does not assume responsibility for any  
accident due to equipment modifications.  
NEVER use accessories or attachments, which are not  
recommended by Multiquip for this equipment. Damage  
to the equipment and/or injury to user may result.  
GLOBUG LIGHTING SYSTEM — OPERATION AND PARTS MANUAL — REV. #2 (11/03/08) — PAGE 5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GB12BW/BS/BP LIGHTING SYSTEM — RULES FOR SAFE OPERATION  
BALLOON SAFETY AND CARE  
When transporting the tripod lighting system, always  
place tripod in the stow position, then place tripod into  
its carrying case.  
To prevent serious burns, NEVER touch or unzip the  
balloon envelope when the lamp is on.  
ALWAYS remove the balloon/lamp assembly from the  
mast when transporting any of the GloBug lighting  
systems. This will prevent damage to the bulb due to  
vibration.  
To prevent the balloon from deformation, NEVER use any  
GloBug lighting system in strong winds.  
DO NOT place the balloon inside its protective cover until  
the lamp has had a sufficient amount of time to cool  
down. This will prevent the balloon's nylon cover from  
being burned (touching the lamp surface).  
NEVER leave the balloon/lamp exposed during transport.  
Exposure to excess wind or rain could damage the  
balloon's nylon cover.  
ALWAYS place the balloon inside its protective cover  
after each use. This will prolong the life of the balloon  
material, keeping it protected from harsh environmental  
elements.  
ALWAYS place the balloon inside its protective cover  
during transport. Be sure the cover is secured tightly  
around the balloon/lamp assembly.  
DO NOT use a damaged balloon. Replace balloon  
immediately if damaged. In addition, a damaged balloon  
will not inflate properly, and may become more damaged  
by touching the hot lamp surface.  
LAMP SAFETY AND CARE  
NEVER leave any grease or oil residue on lamp surface  
when replacing or removing lamp. This can create hot  
spots, reducing the service life of the lamp.  
ALWAYS keep the balloon away from sharp objects and  
excessive amounts of heat (fire!).  
ALWAYS make sure the lamp surface is clean and dry.  
DO NOT use excessive force when zipping and unzipping  
the balloon. Be gentle with the zipper mechanism. If the  
zipper is broken the balloon will become unusable.  
ALWAYS replace with MQ recommended type lamp. See  
parts section of this manual.  
NEVER use force when installing the lamp. Excessive  
force could cause the lamp to break causing bodily harm.  
DANGER - Grounding  
ALWAYS make sure the lamp guard is installed correctly.  
NEVER deform the lamp guard.  
All GloBug lighting systems are  
equipped with a ground pin on the  
power plug. For your protection.  
ALWAYS complete the grounding  
path. NEVER insert the AC power plug  
into a 2-prong receptacle to operate any GloBug lighting  
system.  
NEVER attempt to replace lamp with the power on. Always  
unplug the power cord from the generator or power source  
when changing the lamp.  
NEVER unplug the lamp's AC power cable during  
operation.  
ALWAYS allow a sufficient amount of time for the lamp to  
cool before changing. The possibility exists of severe  
burns.  
When applying power to the lighting system, always  
connect the AC power plug to a 3-prong receptacle that is  
grounded.The possibility exists of Electrical Shock,  
Electrocution, and even Death if the lighting system is not  
grounded.  
ALWAYS have a trained technician to install and remove  
lamp, or replace any damaged fixture wiring.  
PAGE 6 — GLOBUG LIGHTING SYSTEM — OPERATION AND PARTS MANUAL — REV. #2 (11/03/08)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GB12BW/BS/BP LIGHTING SYSTEM — RULES FOR SAFE OPERATION  
Maintenance Safety  
DANGER - Electric Shock Hazards  
NEVER lubricate components or attempt service on any  
ALWAYS keep electrical cords in good condition.Worn,  
bare or frayed wiring can cause electrical  
shock, thus causing Bodily Harm or  
even Death.  
running GloBug lighting system.  
WET  
HANDS  
ALWAYS allow the GloBug lighting system a proper amount  
of time to cool before servicing.  
Keep all GloBug lighting systems in proper working condition.  
NEVER grab or touch a live power  
cord with wet hands, the possibility  
exists of Electrical Shock,  
Fix damage to any GloBug lighting system immediately and  
always replace broken or defective parts.  
POWER  
CORD  
(POWER ON)  
Electrocution, and even Death!  
ALWAYS use the required tool for the job application.  
Using damaged or worn tools or using tools inappropriate  
for the required application is very dangerous, and may  
cause damage to  
DANGER - Electric Shock Hazards  
the machine and  
service personnel.  
NEVER operate any of the  
GloBug lighting systems or  
handle any electrical  
Make sure to use  
the appropriate tool  
for the specific job.  
equipment while standing in  
water, while barefoot, while  
hands are wet, or in the rain.  
A dangerous electrical  
shock could occur causing  
Severe Bodily Harm or  
even Death.  
Emergencies  
ALWAYS know the location of the  
nearest fire extinguisher.  
ALWAYS know the location of the nearest  
first aid kit.  
In emergencies always know the location of the nearest phone  
or keep a phone on the job site. Also know the phone  
numbers of the nearest ambulance, doctor and fire  
department. This information will be invaluable in case of  
an emergency.  
DANGER - Overhead Obstructions  
ALWAYS make sure the  
area above any GloBug  
lighting system is open  
and clear of overhead  
power lines and other  
obstructions.The mast  
can extend in excess of  
13 ft. (4 meters) when an  
optional extension pole is  
used. Contact with  
overhead power lines or o
obstructions could result i
shock, electrocution, caus
damage, Serious Injury o
GLOBUG LIGHTING SYSTEM — OPERATION AND PARTS MANUAL — REV. #2 (11/03/08) — PAGE 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GB12BW/BS/BP LIGHTING SYSTEM — SPECIFICATIONS  
Table 1. Specifications  
GloBug Lighting System  
Model  
GB12BW/BS/BP  
120 VAC  
Input Voltage  
Ballast  
Electronic Ballast (50Hz/60Hz)  
60 Hz Single-Phase  
4.5 Amps  
Frequency  
Max. Current  
Lamp  
Lamp Type  
400 Watt Metal Halide  
34,000  
Lumens  
Light Coverage (360°)  
Surface Temperature (Longitudinal)  
Surface Temperature (Transversal)  
Fan Motor  
90 ft. (27.4 meters)  
476.6°F (247°C) Max.  
417.2°F (214°C) Max.  
Balloon Fan Motor  
Max. Current  
115 VAC, 60 Hz  
.250 Amps  
0.6 inch H20  
.0217 PSI (0.149 kPA)  
Pressure  
Balloon  
Diameter  
33 in. (850 mm)  
Polyester  
Material  
Heat Resisting Temperature  
Melting Temperature  
Internal Temperature of Balloon  
Water Resistance  
Mast (GB12BW)  
Number of Stages  
320 ~ 356°F (160 ~ 180°C)  
500°F (260°C)  
126°F (52°C) Average  
1,500 mm H20  
2
Maximum Height (Standard)  
Extention Pole  
10 feet (3 meters)  
13 feet (4 meters)  
PAGE 8 — GLOBUG LIGHTING SYSTEM — OPERATION AND PARTS MANUAL — REV. #2 (11/03/08)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GB12BW/BS/BP LIGHTING SYSTEM — DIMENSIONS (GB12BW)  
H
I
J
B
K
L
A
E
D
G
C
F
Figure 1. Dimensions (GB12BW)  
TABLE 2. DIMENSIONS  
Reference  
Letter  
Reference  
Letter  
Dimension in. (mm.)  
Dimension in. (mm.)  
A
B
C
D
E
F
52-54 in. (1,305 ~ 1,365 mm.)  
60-62 in. (1,503 ~ 1,572 mm.)  
8.0 in. (190 mm.)  
G
H
I
32 in. (815 mm.)  
33 in. (850 mm.)  
20 in. (500 mm.)  
23 in. (560 mm.)  
50 in. (2,640 mm.)  
J
52 in. (1,300 mm.)  
K
L
73-108 in. (1,837 ~ 2,720 mm.)  
85-120 in. (2,143 ~ 3,026 mm.)  
36 in. (901 mm.)  
GLOBUG LIGHTING SYSTEM — OPERATION AND PARTS MANUAL — REV. #2 (11/03/08) — PAGE 9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GB12BW/BS/BP LIGHTING SYSTEM — DIMENSIONS (GB12BS)  
B
C
D
A
E
Figure 2. Dimensions (GB12BS)  
TABLE 3. DIMENSIONS  
Reference  
Letter  
Reference  
Letter  
Dimension in. (mm.)  
Dimension in. (mm.)  
83.26 -102.95 in.  
(2,115 - 2,615 mm.)  
A
D
E
35.00 in. (900 mm.)  
35.00 in. (900 mm.)  
B
C
52.16 in. (1,325 mm.)  
33.00 in. (850 mm.)  
PAGE 10 — GLOBUG LIGHTING SYSTEM — OPERATION AND PARTS MANUAL — REV. #2 (11/03/08)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GB12BW/BS/BP LIGHTING SYSTEM — DIMENSIONS (GB12BP)  
B
A
Figure 3. Dimensions (GB12BP)  
TABLE 4. DIMENSIONS  
Reference  
Dimension in. (mm.)  
Letter  
A
B
23.00 in. (560 mm.)  
33.00 in. (850 mm.)  
GLOBUG LIGHTING SYSTEM — OPERATION AND PARTS MANUAL — REV. #2 (11/03/08) — PAGE 11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GB12BW/BS/BP LIGHTING SYSTEM — FOOTCANDLE PLOT  
360 degree coverage  
.5  
1
2
5
10  
Values listed as footcandles  
Scale: Grid = 50 ft. (15.25 meters)  
Figure 4. Floodlight Footcandle Plot (BAL 85-Drum Shaped)  
PAGE 12 — GLOBUG LIGHTING SYSTEM — OPERATION AND PARTS MANUAL — REV. #2 (11/03/08)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
(B)  
GB12BW/BS/BP LIGHTING SYSTEM — GENERAL INFORMATION  
The Multiquip GloBug GB12W, GB12BS and GB12BP are  
general purpose portable glare-free lighting systems.Typical  
applications for these types of lighting systems include  
construction sites, emergency road crews and backyard  
parties.  
Balloon Envelopes  
The GloBug lighting system can be configured with a variety  
of balloon envelopes (canopy). Please contact the MQ sales  
department for the balloon of your choice. The GloBug  
GB12BW, GB12BS and GB12BP are shipped from the  
factory with the drum type balloon.  
Lighting  
Multiquip's GloBug lighting system is comprised of one  
"Metal Halide" 400-watt lamp. This lamp has an output of  
34,000 lumens. Typical lighting coverage is in excess 90 ft.  
(27 meters) in a 360 degree pattern.  
Figure 5. GB12BS Attachment (Paver)  
Transport  
Power  
The GB12BW lighting system can be transported (Figure 6)  
quite easily in two carrying cases. The first case (tripod)  
weighs 16 lbs. (7.25 kg) and the second case (lamp assembly)  
weighs 15 lbs. (6.8 kg) for a combined weight of about 31  
lbs. (7.25 kg).  
These GloBug lighting systems are powered by a light weight  
electronic ballast that is built inside the lamp housing. The  
input power requirements for operating the lighting system  
is 120 VAC, 60 Hz @ 4.5 amps.  
Setup (GB12BW)  
For ease of service or transport, the lamp assembly is  
equipped with a quick-disconnect connector that allows the  
lamp fixture to be removed quickly.This feature is extremely  
useful during transport of the lighting system. It is always  
best to remove the lamp and pack it safely so it will not be  
damaged.  
The GB12BW lighting system can be setup quickly and easily.  
Tripod legs can be deployed in one quick easy step and can  
be adjusted to two different heights. The upper position will  
add an additional foot to the mast height. If desired an optional  
35-inch (900 mm) extension pole can be added to the mast  
height. Please contact the MQ sales department if you wish  
to add this feature to your system.  
In addition the unit is equipped with an air-assist mast  
lowering system.This system allows the mast to be retracted  
slowly so that the mast will not fall rapidly when released.  
This feature reduces the amount of vibration or shock to the  
lamp.  
LIGHT  
ASSEMBLY  
TRIPOD  
CARRYING  
Setup (GB12BS)  
CARRYING  
CASE  
CASE  
The GB12BS lighting system (offset pole) is designed to be  
attached to a external piece of a equipment such as a paver  
(Figure 5).This system is equally easy to assemble. Simply  
attach the supplied support clamps to an external pole or  
support and you are ready.  
GB12BP  
When only a complete lamp assembly is required please  
order Model GB12BP.This model number includes the lamp,  
protective guard, balloon protective covering and all other  
components that make up the lamp assemby.  
Figure 6. GB12BW Transporting  
GLOBUG LIGHTING SYSTEM — OPERATION AND PARTS MANUAL — REV. #2 (11/03/08) — PAGE 13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GB12BW/BS/BP LIGHTING SYSTEM — COMPONENTS  
COVER  
CARRYING  
CASE  
4
3
GB12BP  
9
12  
10  
11  
GB12BW  
5
6
2
GB12BS  
13  
16  
1
7
15  
8
14  
Figure 7. Major Components  
PAGE 14 — GLOBUG LIGHTING SYSTEM — OPERATION AND PARTS MANUAL — REV. #2 (11/03/08)  
Download from Www.Somanuals.com. All Manuals Search And Download.