Multiquip Portable Generator DCA600SSK User Manual

DCA600SSK  
WhisperWatt Generator  
WhisperWatt600  
Prime Rating: 480 kW (600 kVA)  
Standby Rating: 528 kW (660 kVA)  
60 Hertz  
WhisperWattStandard Features  
Complete engine analog instrumentation includes DC  
ammeter, oil pressure gauge, water temp. gauge,  
tachometer/hour meter, preheat indicator, manual engine  
speed control, emergency shutdown monitors, and  
emergency stop button.  
Heavy duty, turbocharged, aftercooled, direct  
injection diesel engine provides maximum reliability.  
Brushless alternator reduces service and maintenance  
requirements and meets temperature rise standards for  
Class F insulation systems.  
Complete generator analog instrumentation includes  
voltage regulator control, ammeter phase selector switch,  
voltmeter phase selector switch, AC voltmeter, AC  
ammeter, frequency meter, panel light, and circuit breaker.  
Open delta alternator design provides virtually  
unlimited excitation for maximum motor starting capability.  
Automatic voltage regulator (AVR) provides precise  
regulation.  
Automatic safety shutdown system monitors the water  
temperature, engine oil pressure, overspeed, and  
overcrank. Warning lights indicate abnormal conditions.  
Electronic governor system maintains frequency to  
0.25%.  
Full load acceptance of standby nameplate rating in  
one step (NFPA 110, para 5-13.2.6).  
Auto start/stop control allows generator to start  
automatically in the event of a commercial power failure.  
Sound attenuated, weather resistant, steel housing  
provides operation at 75 dB(A) at 23 feet. Fully lockable  
enclosure allows safe unattended operation.  
Complete power panel. Fully covered; three-phase  
terminals and single phase receptacles allow fast and  
convenient hookup for most applications including  
temporary power boxes, tools and lighting equipment. All  
are NEMA standard.  
Internal fuel tank with direct reading fuel gauges are  
standard.  
Simultaneous single and three phase power.  
Emergency stop switch  
Seven-stage powder coat paint provides durability and  
weather protection.  
EPA-MOH emissions certified.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DCA600SSK  
WhisperWatt Generator  
Specifications  
Generator Specifications  
Design  
Cooling System  
Fan Load  
Revolving field, self-ventilated,  
drip-proof, single bearing  
18.8 hp (14 kW)  
Coolant Capacity (with radiator)  
Coolant Flow Rate (per minute)  
29.6 gallons (112 liters)  
197 gallons (744 liters)  
No. of Poles  
Excitation  
4-pole  
Brushless with AVR  
528 KW (660 KVA)  
480 KW (600 KVA)  
1800  
Standby: 19715 Btu (20.8 MJ)  
Prime: 17535 Btu (18.5 MJ)  
Heat Rejection to Coolant (per minute)  
Heat Radiated to Room (per minute)  
Standby Output  
Prime Output  
Generator RPM  
Standby: 4151 Btu (4.38 MJ)  
Prime: 3697 Btu (3.90 MJ)  
208, 220, 240, 416, 440, 480V  
Reconnectable  
Maximum Coolant Friction Head  
Maximum Coolant Static Head  
Ambient Temperature Rating  
5.0 psi (34 kPa)  
45 feet (14 meters)  
95°F (35°C)  
Voltage — 3Ø  
Voltage — 1Ø  
120, 127, 139, 240, 254, 277V Adjustable  
Star with neutral  
Armature Connection  
Voltage Regulation  
(No load to full load)  
1.0%  
Air  
Power Factor  
Frequency  
0.8  
Standby: 1815 cfm (51 m3/min)  
Prime: 1776 cfm (50 m3/min)  
60 Hz  
Combustion Air  
Frequency Regulation:  
No Load to Full Load  
Isochronous under varying loads from no  
load to 100% rated load  
Maximum Air Cleaner Restriction  
Alternator Cooling Air  
30 in. H2O (7.0 kPa)  
3023 cfm (86 m3/min)  
18891 scfm (535 m3/min)  
46 sq.ft (4.26 sq.m)  
Frequency Regulation:  
Steady State  
0.25% of mean value for constant loads  
from no load to full load  
Radiator Cooling Air  
Insulation  
Class F  
Minimum Air Opening to Room  
Minimum Discharge Opening  
Sound Level dB(A)  
Full load at 23 feet  
16.5 sq.ft (1.5 sq.m)  
75  
Engine Specifications  
Make / Model  
Exhaust System  
4555 cfm (129 m3/min) Standby  
4449 cfm (126 m3/min) Prime  
Komatsu / SA6D170AE-1  
EPA Tier 2 Certified  
Gas Flow (full load)  
Emissions  
858°F (459°C) Standby  
822°F (439°C) Prime  
Starting System  
Electric  
Direct Injection,  
Turbocharged, Aftercooled  
23,150 cc  
Gas Temperature  
Design  
Maximum Back Pressure  
40 in. H2O (10 kPa)  
Displacement  
No. cylinders  
6
Amperage  
Rated Voltage  
1Ø 120 Volt  
1Ø 240 Volt  
3Ø 240 Volt  
3Ø 480 Volt  
Bore x Stroke (mm)  
170 x 170  
Maximum Amps  
1333.3 amps (4 wire)  
666.7 amps (4 wire)  
1443.4 amps  
539 bhp (402 kWm) Standby  
490 bhp (365 kWm) Prime  
257 psi (1773 kPa)  
234 psi (1612 kPa)  
2008 ft./min. (10 m/s)  
Gross Engine Power Output  
BMEP  
721.7 amps  
Piston Speed  
Compression Ratio  
Engine Speed  
14:1  
1800 rpm  
Warranty*  
Overspeed Limit  
Oil capacity gallons (liters)  
Battery  
2100 rpm  
Komatsu Engine  
12 months from date of purchase or 1000 hours (whichever  
occurs first).  
16.1 (60.9)  
12V 200Ah x 2 (24V System)  
Generator  
Fuel System  
12 months from date of purchase or 1000 hours (whichever  
occurs first).  
Maximum Fuel Flow (per hour)  
Maximum Inlet Restriction (Hg)  
Maximum Return Restriction (Hg)  
Fuel Tank Capacity  
Standby: 41 gallons (37 liters)  
0.4 in. (9.8 mm)  
*Refer to the express written, one-year limited warranty sheet for additional  
3.9 in. (98 mm)  
information.  
129.5 gallons (490 liters)  
Fuel Consumption  
full load gph (lph)  
75% load gph (lph)  
50% load gph (lph)  
25% load gph (lph)  
33.9 (128.3)  
26.7 (101.1)  
17.4 (65.9)  
10.6 (40.1)  
Backfeed to a utility system can cause electrocution and/or property damage. Do  
not connect to any building’s electrical system except through an approved device.  
Specifications are subject to change without notice.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DCA600SSK  
WhisperWatt Generator  
Optional Control Features  
Remote speed adjust rheostat — allows for engine speed  
adjustment from the control panel.  
Audible alarm — alerts operator of abnormal conditions.  
Optional Fuel Cell Features  
Trailer fuel tank — a second fuel cell located in the trailer  
allows for extended run time.  
Subbase fuel cells (double wall) — Additional fuel cell for  
extended runtime operation. Contains a leak sensor, low  
fuel level switch, and a secondary containment tank. UL142  
listed.  
Optional Generator Features  
Battery charger — provides fully automatic and self-  
adjusting charging to the generator's battery system.  
Low coolant level shutdown — provides protection from  
critically low coolant levels. Includes control panel warning  
light.  
12 hours of minimum run time.  
24 hours of minimum run time.  
Jacket water heater — for easy starting in cold weather  
climates.  
Special batteries — long life batteries provide extra engine  
cranking power.  
Spring Isolaters — provides extra vibration protection for  
standby applications.  
Optional Output Connections  
Fuel / water separators — removes condensation from fuel  
for extended engine life.  
Pin and Sleeve Connectors — provides industry standard  
connectors for all voltage requirements.  
Trailer mounted package — highway legal, drop deck,  
semi-trailer with air brakes. Extra capacity fuel tanks are also  
available.  
Output cable — available in any custom length and size  
configuration.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DCA600SSK  
WhisperWatt Generator  
Dimensions  
Weight  
Dry Weight  
19,553 lbs (8,869 kg)  
21,561 lbs (9,780 kg)  
Wet Weight  
Units mfg. by Denyo Mfg. Corp.  
Your MQ Power dealer is:  
MQ POWER  
POST OFFICE BOX 6254  
CARSON, CA 90749  
310-537-3700  
800-421-1244  
FAX: 310-632-2656  
© COPYRIGHT 2005, MULTIQUIP INC.  
Rev. 4 (7-05)  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Multiquip Appliance Trim Kit MVH 402GHB User Manual
Multiquip Appliance Trim Kit MVH406DSCPAS User Manual
Multiquip Chainsaw SP706016 User Manual
Multiquip Portable Generator dca 60ssai User Manual
Multiquip Trash Compactor MVH R60H User Manual